Longwall equipment

MSL 1203-SS-1,2/500

MSL 1203-SS-1,2/500
Application

The station is designed for remote stepless start control and stop control of squirrel-cage motors, which are operated in three-phase networks with insulated transformer neutral with 660V voltage, 1140 V in gas-(methane) and dust-hazardous mines.

This station has PB Exdiaibml explosion-proof design.

Compact station with cushion start is built on the base of Siemens SIPLUS S7-200 industrial controller using start-control equipment of Bartec company and cushion start control system of Siemens company. .

Basic specifications

System nominal voltage, V

660/1140

Power frequency, Hz

50

Maximum amount of rated load current, A:

- with thyristor start

- without thyristor start



500

500

Tap-off number, pcs.:

- with thyristor start

- without thyristor start



4

4

Auxiliary tap-off voltage, V

42

Load capacity of auxiliary tap-off, A

4

Operating regime:

- continuous;

- intermittent continuous

Dimensional specifications, mm, max:

- length, mm

- width, mm

- height, mm



2420

790

1060

Weight, kg, max

1800

Protection level

IP 54

Climatic version in accordance with GOST 15150-69

У5